Core cutting line supplier factory by Canwin
Premium cut to length line manufacturer factory: What does the rated value on the nameplate of the transformer mean? The rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer. Usually includes the following aspects: Rated capacity: The rated capacity of a transformer refers to the maximum load electric power that the transformer can continuously supply. For example, a 10MVA transformer means that the transformer’s maximum load can reach 10 megawatts. Rated voltage: The rated voltage of the transformer refers to the design voltage of the transformer. For example, a 220kV/110kV transformer means that the input voltage of the transformer is 220 kV and the output voltage is 110 kV. Rated frequency: The rated frequency of a transformer refers to the power frequency for which the transformer is designed. In China, the power frequency is usually 50Hz. Short-time withstand current: The short-time withstand current of a transformer refers to the maximum current value that the transformer can withstand in a short period of time. For example, the short-term withstand current of a transformer is 50kA, which means that the transformer can withstand an instantaneous current of up to 50 kA. Find additional details on slitting line machine.
Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.
Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.
Canwin electrical equipment manufacturer provides diversified choices for customers. Distribution cabinet, power transformer equipment are available in a wide range of types and styles, in good quality and in reasonable price.Canwin collects scientific and rigorous of manufacturing and quality control management experience, in order to meet the different countries in different fields of capacitor products provide efficient, high-quality, fast service, so that the “Canwin”brand products win a good reputation all over the world.
A transformer coil winding machine is an intricate piece of machinery with an essential role in the manufacturing of transformers, combining modern technology and meticulousness to create high-quality products efficiently. The process starts with the feeding of copper wire into the machine, which passes through a line-up of calibrations guides and tensioners designed to secure alignment and prevent damage. An automated system then causes rotation, gradually looping copper wire around the transformer coil. A computerized system oversees variables such as speed, pitch control, layer count and insulation thickness for consistent turns. Moreover, for distinct transformer models or designs, these machines can be fitted with extra features such as automatic lead cutting and tapping mechanisms for increased versatility and productivity.
CANWIN adheres to the business policy of high -end manufacturing, intelligent equipment + intelligent factory, comprehensively improves the quality of products and the cutting speed and precision, accelerates the transformation of development mode, and promotes the upgrading of industrial structure In terms of new product development, the company relies on the “Guangdong university of technology provincial thin plate processing and cutting technology engineering center”as an innovation platform, continuously trains and introduces technological talents, and provides intellectual support for the company to enhance soft power and rapid development.
Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.
The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. Find additional details on https://www.canwindg.com/
Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.
In terms of productivity, poor PQ can cause unscheduled downtime due to equipment malfunctions or system failures. This unpredictability can significantly disrupt operations, leading to lower productivity levels and potential revenue losses. Moreover, poor PQ can lead to diminished energy efficiency. Transformers operating under poor power quality conditions often require more power to function, leading to increased energy consumption and higher operating costs. The excess power demand could also strain the electrical grid, leading to further inefficiencies and disruptions. Additionally, the costs associated with repairing or replacing damaged equipment due to poor power quality can be substantial. There are also indirect costs to consider, such as those associated with investigation and troubleshooting of power quality issues.